Showing results: 106 - 120 of 403 items found.
-
AMETEK Programmable Power, Inc.
Electronic loads have found a variety of applications ranging from power converter testing to current modulation. A large range of power sources can be tested using an electronic load from converters, inverters and UPSs to electrochemical sources such as batteries and fuel cells.
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed SECONDARY CURRENT INJECTION TEST TROLLEY for Switchgear items, CT manufacturer and where three phase current application is called for. It is low Voltage, 3 phase Current source with control circuitry, digital read out for test current and trip time measurement. We can select different CT ranges for each phase independently and adjust the current as per the required test Current.
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed primary and secondary Current injection test trolley for Switchgear manufacturers for testing of ACB , MCB , MCCB. It is low Voltage high Current source with control circuitry, digital read out for test current and trip time measurement. We can select different links of CT range as per the required test Current.
-
VX Instruments GmbH
Source and Measurement Units (SMUs) are devices that generate voltages or currents and can measure them simultaneously using the integrated measurement units (VMU, CMU).
-
1620A -
Ballentine Laboratories, Inc.
The 1620A provides high accuracy current levels from dc to over 10 kHz for calibrating ammeters, current transformers and shunts. It also provides output current up to 100 Amperes and as such may also be used as a high accuracy power supply, and as a power source in welding and bonding applications.
-
1043 -
The Eastern Specialty Company
The Current Transformer Burden Test Set (Catalog No. 1043) is a simple and inexpensive means whereby a current transformer installation may be quickly checked for many sources of trouble. The tests are made without interrupting the customer’s service and while the load is on.
-
C&C Instruments Co.
Power Source : Wide Input(90V to 260V~) 50Hz/60Hz Output Current : 0~3A, 1A(Fixed) Rs-232C Interface(Option) Programmable(Option)
-
HIOKI E.E. Corp
Combine with specially designed power source unit PSU-8541 for high-speed measurement Resistance measurement Max. 310^16 Current measurement 0.1fA to 100A
-
HPS -
RARA Electronics Corporation
*Up to 250W on heat sink*Max. current limit 387AExcellent long term stability & short term stability*Low temperature coefficient of resistance (TCR)*High current sensing & reference restores in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
TH1775 -
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
16200B -
Keysight Technologies
The 16200B test fixture is designed to operate with high frequency LCR meters and impedance analyzers. It allows you to supply a bias current across the device of up to 5 Adc through a 7 mm port by using an external DC current source.
-
SCR ELEKTRONIKS
SCR ELEKTRONIKS have developed Test Bench for Circuit Breaker to test 2, 5 & 10 at a time. Panel is provided with constant DC current source.
-
BV0023B -
Keysight Technologies
The PathWave BenchVue USB modular SMU pro software configures voltage and current source, range and limit for each SMU channel and log unrestricted data.
-
Suzhou 3ctest Electronic Co.,Ltd.
Surge pulses occur due to direct or indirect lighting strokes to an external circuit. This leads to current or electromagnetic fields causing high voltage or current transients. Another source for surge pulsed is switching transients originating from switching disturbances and system faults.
-
72-6694 CAL -
Tenma
The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).